I’m getting increasingly frustrated trying to get my printer calibrated. I’ve done a bed calibration using screws_tilt_calculate, and that’s all nice and good. Got a bed mesh variance of 0.19mm which seems great.
Now for the z-offset, it won’t let me get the nozzle low enough. No matter how low I set the Z minimum, it won’t let me get closer than about 0.5mm to the bed. I’ve tried setting the position_min in [stepper_z] anywhere from 0 to -9 and I get the same result every time.
If I raise the bed, the probe adjust its height accordingly, so the result is the same.
What can I do to fix this?
This. Checkout the Klipper documentation at https://www.klipper3d.org/Probe_Calibrate.html#calibrating-probe-z-offset